Hirschmann GRS105-24TX/6SFP-2HV-3AUR Chinja
Tsanangudzo Pfupi
Iyo GREYHOUND 105/106 switch 'inochinjika dhizaini inoita iyi ive yeramangwana-uchapupu networking mudziyo unogona kushanduka padivi penetiweki bandwidth uye simba rinodiwa. Nekutarisa pakuwanikwa kwenetiweki kwakanyanya pasi pemamiriro eindasitiri, idzi switch dzinogonesa iwe kuti usarudze chiteshi chemuchina uye mhando - kunyangwe ichikupa iwe kugona kushandisa iyo GREYHOUND 105/106 nhevedzano senge backbone switch.
Product Detail
Product Tags
Commeerial Date
Product tsananguro
| Type | GRS105-24TX/6SFP-2HV-3AUR (Kodhi yechigadzirwa: GRS105-6F8T16TSGGY9HHSE3AURXX.X.XX) | 
| Tsanangudzo | GREYHOUND 105/106 Series, Managed Industrial Switch, dhizaini isina fan, 19" rack gomo, maererano neIEEE 802.3, 6x1/2.5GE +8xGE +16xGE Dhizaini | 
| Software Version | HiOS 9.4.01 | 
| Chikamu Nhamba | 942287013 | 
| Port mhando uye uwandu | 30 Ports pamwero, 6x GE/2.5GE SFP slot + 8x FE/GE TX ports + 16x FE/GE TX ports | 
Zvimwe Interfaces
| Simba rekupa/kunongedza kuonana | Magetsi ekuisa 1: IEC plug, Signal yekubata: 2 pini plug-in terminal block, Simba rekuisa rekuisa 2: IEC plug | 
| SD-kadhi slot | 1 x SD kadhi slot yekubatanidza iyo otomatiki yekumisikidza adapta ACA31 | 
| USB-C | 1 x USB-C (mutengi) yekutonga kwenzvimbo | 
Network saizi - urefu of cable
| Twisted pair (TP) | 0-100 m | 
| Single mode faibha (SM) 9/125 µm | ona SFP modules | 
| Single mode faibha (LH) 9/125 µm (kurebesa transceiver) | ona SFP modules | 
| Multimode faibha (MM) 50/125 µm | ona SFP modules | 
| Multimode faibha (MM) 62.5/125 µm | ona SFP modules | 
Network saizi - cascadibility
| Mutsetse - / nyeredzi topology | chero | 
Simba zvinodiwa
| Kushanda Voltage | Simba rekushandisa 1: 110 - 240 VAC, 50 Hz - 60 Hz , Simba rekushandisa 2: 110 - 240 VAC, 50 Hz - 60 Hz | 
| Simba rekushandisa | Basic unit ine one power supply max. 35W | 
| Simba rinobuda muBTU (IT)/h | max. 120 | 
Software
| 
 Kuchinja | Yakazvimirira VLAN Kudzidza, Kukurumidza Kuchembera, Static Unicast/Multicast Kero Entries, QoS / Port Prioritization (802.1D/p), TOS/DSCP Kutungamira, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), VLAN Usingazivi Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMoping/v1S) Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP) , IP Ingress DiffServ Classification uye Policing, IP Egress DiffServ Classification uye Policing, Protocol-based VLAN, MAC-based VLAN, MAC-based VLAN, MAC-based | 
| Redundancy | HIPER-Ring (Ring Switch), Link Aggregation neLACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), RSTP 802.1D-2004 (IEC62439-1), RSTP Guards, VRRP, VRRP Tracking, HimentsRP (VRRP) | 
| Management | Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, IPv6 Management, Traps, SNMP v1/v2/v3, Telnet , DNS Client, OPC-UA Server | 
| Diagnostics | Management Kero Kusawirirana Kuona, MAC Notification, Signal Contact, Device Status Chiratidzo, TCPDump, LEDs, Syslog, Kuramba Kutema paACA, Port Monitoring ine Auto-Disable, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed uye Duplex Monitoring, Mirroring, 1 Port, RMON19 Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, System Information, Self-Tests paCold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump , Email Notification, RSPAN, SFLOW, VLAN Mirroring , Kero Conflict Detection for routing interfaces. | 
| Configuration | Automatic Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config pane iri kure server paunenge uchichengetedza, Bvisa gadzirisa asi chengetedza IP marongero, BOOTP/DHCP Client neAuto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN Adapter, ACADiscovery cardy, ACADia3 kadhi reVLAN, AutoConfigusSD Relay neSarudzo 82, Command Line Interface (CLI), CLI Scripting, CLI script inobata ENVM pabhutsu, Yakazara-inoratidzwa MIB Tsigiro, Context-sensitive Rubatsiro, HTML5 yakavakirwa Management. | 
| 
 Chengetedzo | MAC-based Port Security, Port-based Access Control ine 802.1X, Guest/VLAN isina kutenderwa, Integrated Authentication Server (IAS), RADIUS VLAN Assignment, Denial-of-Service Prevention, VLAN-based ACL, Ingress VLAN-based ACL, Basic ACL, Access to Management inodziviswa Kuchengetedzwa Kwekuchengetedzwa, VLAN. HTTPS Certificate Management, Restricted Management Access, Yakakodzera Kushandisa Banner, Configurable Password Policy, Configurable Number ye Login Kuedza, SNMP Logging, Multiple Privilege Level, Local User Management, Remote Authentication kuburikidza neRADIUS, User Account Locking, Password shanduko paunotanga kupinda, RADIUS Policy Assignment, MAC-Aupassation Performance, Aupass Format sarudzo dzeMAC authentication bypass, DHCP Snooping, IP Source Guard, Dynamic ARP Inspection, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, Egress VLAN-based ACL, ACL Flow. | 
| Nguva yekuyananisa | PTPv2 Transparent Clock mbiri-nhanho, PTPv2 Boundary Clock, BC ine Kusvika 8 Sync / s , Buffered Real Time Clock, SNTP Client, SNTP Server | 
| Industrial Profiles | EtherNet/IP Protocol Modbus TCP PROFINET Protocol | 
| Miscellaneous | Manual Cable Kuyambuka, Port Power Down | 
| Routing | IP/UDP Mubatsiri, Yakazara Wire-Speed Routing, Port-based Router Interfaces, VLAN-based Router Interfaces, Loopback Interface, ICMP Sefa, Net-inotungamirwa Nhepfenyuro, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Static Unicast Routing, Proxy Route Tracking, | 
| Multicast routing | IGMP v1/v2/v3, IGMP Proxy (Multicast Routing) | 
Ambient conditions
| Kushanda tembiricha | -10 - +60 | 
| Cherechedza | 837 450 | 
| Kuchengetedza / kupisa kwekutakura | -20 - +70 °C | 
| Relative humidity (isina-condensing) | 5-90 % | 
Mechanical kuvaka
| Dimensions (WxHxD) | 444 x 44 x 355 mm | 
| Kurema | 5 kg inofungidzirwa | 
| Mounting | Rack mount | 
| Dziviriro kirasi | IP30 | 
Hirschmann GRS 105 106 Series GREYHOUND Switch Available Models
GRS105-16TX/14SFP-2HV-3AUR
GRS105-24TX/6SFP-1HV-2A
GRS105-24TX/6SFP-2HV-2A
GRS105-24TX/6SFP-2HV-3AUR
GRS106-16TX/14SFP-1HV-2A
GRS106-16TX/14SFP-2HV-2A
GRS106-16TX/14SFP-2HV-3AUR
GRS106-24TX/6SFP-1HV-2A
GRS106-24TX/6SFP-2HV-2A
GRS106-24TX/6SFP-2HV-3AUR
Zvigadzirwa zvinoenderana
-                Hirschmann MAR1030-4OTTTTTTTTTTTTT999999999999SM...Tsanangudzo Yechigadzirwa Tsananguro Indasitiri yakachengetedzwa nekukurumidza / Gigabit Ethernet Shandura zvinoenderana neIEEE 802.3, 19" rack gomo, isina fan Dhizaini, Chitoro-uye-Pamberi-Kuchinja-Kuchinja Port mhando uye huwandu Muhuwandu 4 Gigabit uye 12 Fast Ethernet ports \\ GE 1 - 4: 1000BASE-FX, SFE 1 uye SFE 1 10/100BASE-TX, RJ45 \\\ FE 3 uye 4: 10/100BASE-TX, RJ45 \\\ FE 5 uye 6: 10/100BASE-TX, RJ45 \\\ FE 7 uye 8: 10/100BASE-TX ...\ FE 5 
-                Hirschmann BRS20-1000S2S2-STCZ99HHSES ChinjaCommerial Date Technical Specifications Tsanangudzo Yechigadzirwa Tsananguro Yakagadziriswa Indasitiri Switch yeDIN Rail, isina fan dhizaini Fast Ethernet Type Software Version HiOS 09.6.00 Port mhando uye uwandu 20 Ports zvachose: 16x 10/100BASE TX / RJ45; 4x 100Mbit/s faibha; 1. Uplink: 2 x SFP Slot (100 Mbit / s); 2. Uplink: 2 x SFP Slot (100 Mbit / s) More Interfaces Simba rekupa / chiratidzo chekubatanidza 1 x plug-in terminal bloc... 
-                Hirschmann GRS106-16TX/14SFP-2HV-3AUR ChinjaCommerial Date Chigadzirwa tsananguro Rudzi GRS106-16TX/14SFP-2HV-3AUR (Chigadzirwa kodhi: GRS106-6F8F16TSGGY9HHSE3AURXX.X.XX) Tsananguro GREYHOUND 105/106 Series, Managed Industrial Switch, rackless rack, EE2 dhizaini, EE2" dhizaini, EE2" 6x1/2.5/10GE +8x1/2.5GE +16xGE Design Software Version HiOS 9.4.01 Chikamu Number 942287016 Port type uye uwandu 30 Ports muhuwandu, 6x GE/2.5GE/10GE SFP(+) slot + 8x GE/2.51 SFP Slot + 2.51 SFP... 
-                Hirschmann DRAGON MACH4000-52G-L3A-MR SwitchCommerial Date Chigadzirwa tsananguro Rudzi: DRAGON MACH4000-52G-L3A-MR Zita: DRAGON MACH4000-52G-L3A-MR Tsananguro: Yakazara Gigabit Ethernet Backbone Backbone Shandura neanosvika 52x GE ports, modular dhizaini, fan unit yakaiswa, mapofu mapaneru emutsara kadhi uye magetsi emagetsi slots, maficha epamusoro ekuisa magetsi Hirout. 09.0.06 Chikamu Nhamba: 942318003 Port mhando uye huwandu: Ports muhuwandu kusvika makumi mashanu neshanu, ... 
-                Hirschmann RS20-0800M2M2SDAE Yakakwana Yakagadziriswa Mu...Chigadzirwa Tsananguro Yakagadziriswa Fast-Ethernet-Switch yeDIN njanji chitoro-uye-mberi-kuchinja, fanless dhizaini; Software Layer 2 Enhanced Part Number 943434003 Port type uye uwandu 8 ports muhuwandu: 6 x chiyero 10/100 BASE TX, RJ45; Uplink 1: 1 x 100BASE-FX, MM-SC; Uplink 2: 1 x 100BASE-FX, MM-SC Mamwe mainterface ... 
-                Hirschmann SFP GIG LX/LC SFP ModuleTsanangudzo yechigadzirwa Rudzi rwechigadzirwa: SFP-GIG-LX/LC Tsananguro: SFP Fiberoptic Gigabit Ethernet Transceiver SM Chikamu Nhamba: 942196001 Chiteshi mhando uye huwandu: 1 x 1000 Mbit/s ine LC connector Saizi yeNetwork - kureba kwetambo Single mode fiber (SM) 9/120 µnk3 µm125 µm3 µm µm µm 125 µnkt µm3 µm. nm = 0 - 10.5 dB; A = 0.4 dB/km; 
 
                 